Crewman injured when steel plates fell against him

  • Safety Flash
  • Published on 23 December 2011
  • Generated on 13 July 2026
  • IMCA SF 14/11
  • 2 minute read

A Member has reported an incident in which a crewman was injured by steel plates falling whilst being placed in storage.

What happened?

The incident happened on a vessel when four crew members were moving steel plates (each weighing 250 kg) from the bosun’s store to the welding shop. Their intent was to create a new storage area in the welding shop for these steel plates. The new storage area was to be at a slight elevation of approximately 75 cm off the deck.

The plates were moved by overhead hoisting equipment from the bosun’s store to the welding shop. Because there were some brackets welded on the bulkhead, the steel plates had to be pushed into place manually once they were lifted onto the elevated storage area. Because several plates were to be stored in the storage area they were temporarily secured with clamps. When all plates were in their final position, steel poles were welded on the deck to secure them in place.

During the job a securing clamp was inadvertently knocked off while crew members manually moved one of the plates into its final position. As a result the plates fell over towards one of the crew members. He saw them coming, but owing to the weight of the plates he was unable to push them back and instead tried to jump out of the way. He was not successful; the plates came into contact with his body and he hit his head on a nearby column, resulting in small fractures to the skull and shoulder.

welding bay storage area

welding bay storage area

securing clamp

securing clamp

swipe right

 

What were the causes?

An investigation revealed that:

  • The job was considered ‘routine’ and no Job Hazard Analysis was conducted. Though the handling of steel plates is a ‘routine’ activity on board this vessel, the creation of a new storage area was not ‘routine’.

  • Manual handling of steel plates weighing 250 kg is inherently risky.

  • A workplace inspection prior to the activity would have revealed the risks posed by the obstructing brackets on the bulkhead.

  • The clamps used to secure the steel plates temporarily were not adequate or safe for the activity being conducted.

  • There were too many people in too small a work space.

Latest Safety Flashes:

Severe injuries following falling off a freight container

A truck driver slipped and fell from a container leading to severe injury.

Read more
Watertight doors left open

Watertight doors in the Engine Room and fire doors in the accommodation were observed open on several occasions during a management audit.

Read more
Crew member injured during mooring operation

A crew member used their foot to slow down a running mooring rope, causing them to fall to the deck.

Read more
Worker got something in the eye – safety glasses slightly askew

A workers safety glasses were slightly offset (creating a small gap) which allowed a fragment of hot slag to get in his eye.

Read more
Fire in tumble dryer

A fire was discovered within one of the vessel laundry dryers.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.