Electric shock after touching an electrical switch in the steering room.

What happened?

A shore representative visiting the vessel experienced an electric shock after touching an electrical switch in the steering room. Stop the Work authority was exercised; the electrical switch was immediately isolated and subsequently removed for investigation.

What went wrong?

  • The switch had been removed from the wall, but not re-installed, during maintenance.
  • There had subsequently been engine room washing following major repairs, and the water ingress arose at that time.
  • The switch had been unprotected and remained live, not isolated, during the engine room washing.
Electric shock after water ingress to switch

Appearance of electrical switch to visitor

Electric shock after water ingress to switch

Electrical switch showing clear sign of water ingress

Lessons learned

  • Ensure maintenance work is fully completed before returning equipment or systems to service.
  • Arrange appropriate isolation and protection of electrical connections and switches during any washing or cleaning of an area.
  • Ensure all parts of the vessel electrical systems and equipment are regularly inspected and tested by a Competent Person and the results recorded in the Planned Maintenance System.

Latest Safety Flashes:

LTI: Finger injury during emergency recovery of ROV

A worker suffered a serious finger injury when their finger was caught between a crane wire and the recovery hook on an ROV.

Read more
BSEE: recurring hand injuries from alternative cutting devices

The United States Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert 487.

Read more
NTSB: Crane wire failure

The National Transportation Safety Board of the United States (NTSB) published "Safer Seas Digest 2023".

Read more
Hot work performed outside of Permit to Work (PTW) boundary limit

A near miss occurred when a third-party contractor working removed a trip hazard from the vessel main deck, using a cutting torch and grinding disc.

Read more
Vital safety information (height of vehicle) found incorrect

“Height of vehicle” information displayed on a truck, was found to be incorrect.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.