NTSB: watertight doors – vessel sank after flooding

  • Safety Flash
  • Published on 20 June 2022
  • Generated on 28 November 2026
  • IMCA SF 15/22
  • 2 minute read

The National Transportation Safety Board (NTSB) of the United States has published findings from an investigation into the flooding and sinking of a towing vessel.

What happened?

A towing vessel was in transit when its stern compartments began flooding. The three crew members aboard attempted to pump out the water but were unsuccessful and subsequently abandoned the vessel. They were rescued, and the towing vessel later sank close inshore. No injuries were reported. An oil sheen was visible after the vessel sank. The vessel was later recovered but was considered a constructive total loss valued at $968,000.

What went wrong?

Investigation determined that the probable cause of the sinking of the towing vessel was unsecured or open aft deck hatches, which resulted in the flooding of the vessel’s aft compartments from water on deck, leading to progressive flooding of other compartments through openings in watertight bulkheads. Contributing to the flooding of the vessel was the owner’s lack of an effective hull inspection and maintenance program.​

Lessons Learned

The NTSB noted that in the last five years it has investigated five casualties involving towing vessels whose weather decks and openings were in poor condition—leading to flooding and subsequent sinking.

  • To protect vessels and the environment, it is good marine practice for owners to conduct regular oversight, inspection and maintenance of hulls, including between drydock periods, regardless of inspection requirements.
  • An effective maintenance and hull inspection program should proactively address potential steel wastage, identify hull and watertight integrity deficiencies, and ensure corrosion issues are repaired in a timely manner by permanent means.​

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.