Potential interference of VHF-FM radio and AIS reception

  • Safety Flash
  • Published on 30 October 2018
  • Generated on 24 November 2026
  • IMCA SF 24/18
  • 2 minute read

The United States Coast Guard (USCG) have published Safety Alert 13-18, regarding numerous reports on poor reception of VHF frequencies used for radiotelephone, digital selective calling (DSC) and automatic identification frequencies (AIS).

What happened?

  • Poor reception was noticed when around LED lighting on-board vessels (navigation lights, searchlights and floodlights); interior and exterior lights and adornment lighting are just some of the few lighting systems containing LED lighting.
  • The radio frequency (RF) interference caused was found to create potential safety hazards.
  • A maritime rescue coordination centre was unable to contact a ship involved in a traffic separation scheme incident by VHF radio. The ship had also experienced very poor AIS reception.
  • Other ships in various ports experienced degradation of VHF receivers, including AIS, caused by their LED navigation light. LED lighting installed near VHF antennas has shown to interfere with the reception.
Lighting on vessel at night
VHF radio

What lessons were learned?

  • RF interference may not be immediately obvious to maritime radio users. However, it may be possible to test for interference caused by LEDs;
    • turn off LED light(s)
    • tune the VHF radio to a quiet channel
    • adjust the VHF radio’s squelch control (until the radio outputs audio noise)
    • re-adjust the VHF radio’s squelch control until the audio noise is quiet (slightly above the noise threshold)
    • turn on the LED light(s) – if the radio outputs audio noise, then the LED lights have raised the noise floor
    • if the radio does not output audio noise, then the LED lights have not raised the noise floor
  • If the noise floor is found to have been raised, then it is likely that both shipboard VHF marine radio and AIS reception are being degraded by LED lighting.

The USCG has requested that anyone experiencing this kind of problem, to send reports to Coast Guard Navigation Center.

The full safety alert can be found on the USCG’s website.

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.