LTI: Gangway collapsed

  • Safety Flash
  • Published on 6 December 2023
  • Generated on 17 November 2026
  • IMCA SF 28/23
  • 2 minute read

A person was badly injured when a gangway collapsed as he was using it

What happened?

The incident occurred when the injured person requested permission to leave Vessel 2, which was moored outside of and alongside Vessel 1, which was alongside in a shipyard.

The injured person was unaware that Vessel 1 was undergoing engine tests, and the gangway was not in use. However, the gangway had not been removed completely, due to scaffolding structure being in the way. 

There was no gangway watch nor were there any signs and barriers in place. As the injured person started to walk down the gangway, it collapsed causing the person to fall and break both heels.

Medical evacuation was arranged and fracture of both heels was confirmed afterwards.

Gangway collapsed while in use, injured party broke both heels

Gangway collapsed while in use - the injured party broke both heels

What went wrong?

  • The vessel gangway was moved partially instead of fully and properly. This happened because scaffolding was installed on board the vessel, resulting in a lack of space to store the gangway.

  • The partial removal of the gangway, though it was known to be incorrect, was left unchallenged by everyone involved.

  • The removal of the gangways on both vessels (due to engine tests) had been announced and was recorded in the bridge logbooks, but the injured person was still granted permission to leave the vessel.

  • There were no rigid barriers or safety signs at the access point (an open door) to dissuade or prevent persons from using the  gangway.

  • There was no gangway watch person present.

  • There was no lighting over the gangway area (the event occurred in the hours of darkness).

Lessons learned

  • More “joined up thinking” needed – better communication of, and understanding of, what is going on.

  • Ensure appropriate supervision of crew at all times.

  • Ensure that there is a gangway watch – as mandated in ISPS – at all times, and ensure that access to and from the vessel is properly lit.

  • Ensure barriers and signage indicating a hazard or dangerous area, are fit for purpose and cannot be got round in any way.

  • Stop and think! Take the time to think things through.

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.