Incidents in small workboats used in the offshore renewables sector
- Safety Flash
- Published on 20 December 2016
- Generated on 8 November 2026
- IMCA SF 35/16
- 4 minute read
Jump to:
- Incident 1: Incomplete engine service by vessel crew leads to an auxiliary power unit engine breakdown
- What happened?
- Incident 2: Navigational near-miss with a third-party vessel whilst working in a DP 500m zone
- Our member recommended the following:
- Incident 3: CTV was left with no-one in command during passenger transfer via boat landing
- Related Safety Flashes
A Member has reported a number of incidents involving the small workboats used in the offshore renewables sector.
Incident 1: Incomplete engine service by vessel crew leads to an auxiliary power unit engine breakdown
After servicing of a vessel’s electrical generator (auxiliary power unit) it was found that the motor could not be returned to a functioning service.
Initial investigation revealed a lack of coolant movement, causing the motor to overheat which in turn was causing the generator to automatically shut down. Further investigation (not by the crew) found a blockage was located within the coolant line. The blockage was a wooden bung.
What happened?
When performing a minor repair, a wooden bung had been used to prevent any coolant loss during removal of a pipe. The repair was completed and the pipe was replaced, but without the bung being removed.
- Causal factor: poor mechanical practice.
Recommendation: ensure proper record-keeping and logging of events during repairs, particularly when repairs span several shifts, to ensure that what has happened is clearly understood by all involved.
Incident 2: Navigational near-miss with a third-party vessel whilst working in a DP 500m zone
Whilst approaching the boat landing of an accommodation vessel stationed on DP, a Crew Transfer vessel (CTV) had to abandon its manoeuvre as another CTV came into visibility with a direct heading for collision. Both vessels were able to navigate away from a collision at the last moment but it was believed that the distance between the two CTVs came within one boat length. The incident occurred in heavy fog.
After waiting within the 500m zone of the DP stationed accommodation vessel, the CTV received a call from the accommodation vessel to make an approach to the boat landing, and started to do so, following departure of another vessel. In the final approach (two boat lengths out) the Master spotted an unknown CTV approaching fast on the starboard side in the heavy fog. This CTV had not called into the 500m zone (there was no procedure in place to do so). Because the Master of the CTV was concentrating on the boat landing, he was not monitoring his radar, and had not spotted the incoming CTV earlier. Once he made visual contact with the approaching CTV both vessels raised power and engaged reverse thrust. The vessels both stopped in time. Eye witnesses on board the accommodation vessel say they came within one boat length of collision.
Our member concluded that the Master of the unknown incoming CTV was navigating too fast for the localised weather conditions (heavy fog) and local navigable environment (three vessels in 100m). He had not informed any of the other vessel in his proximity of his position, speed or destination.
Our member recommended the following:
- There should be a formal 500m (safety zone) procedure in place around the DP Accommodation Vessel.
- Even when there is not an exclusion zone in place, it is good practice when travelling in reduced visibility to maintain communications with localised vessels at all times and reduce speed, as identified in COLREGS.
Incident 3: CTV was left with no-one in command during passenger transfer via boat landing
Whilst performing passenger transfer with a jack-up barge in port, with the bow pushed against a boat landing, the Master of the CTV left the helm and went onto the back deck for a cigarette leaving the vessel “not under command”.
One of the passengers already on board the CTV (the Captain of the jack-up barge) noticed this and ordered the CTV Master to return to the helm. The Master returned and the transfer continued, the crewman (busy with the transfer interface) had been unaware that the Master, after giving him the visual signal to begin transfer, had then left the helm.
Our member concluded that the CTV Master, due to his own complacency, decided that he was able to leave the helm position without a change to the CTV’s position on the boat landing (whilst underway). He knew that by doing so he was knowledgably failing to comply with the written safe working procedures of the company.
This was a serious neglect of safety. The Master, in consideration of the potential results of this neglect of safety and his previous record within the company, was relieved of his duties.
An onsite safety meeting was held with the crew and the shore based manager to highlight the correct company procedures and good safety practices.
Related Safety Flashes
-
IMCA SF 25/16
3 October 2016
-
IMCA SF 12/15
28 August 2015
-
IMCA SF 07/15
29 May 2015
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.