Leak in hot water system for saturation divers

  • Safety Flash
  • Published on 9 January 2024
  • Generated on 18 September 2025
  • IMCA SF 01/24
  • 1 minute read

Divers Hot Water Unit had a water leak.

What happened?

During saturation diving operations between bell runs it was noted that Divers Hot Water Unit #2 had a water leak. The leak was investigated and located, but was found to be in a place with very poor access. There was a small hole in a pipe, which on investigation was found to be a bigger hole under surface corrosion.

The Dive Supervisors and Dive Superintendent were immediately informed about the issue, and diving was suspended due to there being no backup for the remaining Hot Water #1 Unit.

What went wrong?

  • Due to very limited access, it was not possible to inspect the tank outlet of the 4″ closed circuit pipework.
  • External corrosion had over the years completely corroded the 4mm pipe in a very limited area.

What was the cause?

  • The direct cause: corrosion over many years.
  • The root cause: The inaccessible location [for visual inspection] of the pipe.
Leak in hot water system for saturation divers

The hole at 6 o’clock in the water intake

Leak in hot water system for saturation divers

Sleeve welded at the area of corrosion

Leak in hot water system for saturation divers

Location of the hole, inaccessible for visual inspection. Picture shows the back part of the unit mounted against a wall

Actions

  • Sleeve welded on the leaky area;
  • Hot Water Unit #1 was inspected and no defects found;
  • Consider wall thickness measurements of old pipes.

Latest Safety Flashes:

SWL plate dropped from crane block

An “SWL” plate weighing 0.9kg fell from the auxiliary hook block and landed on the main deck of a newly purchased vessel.

Read more
Unsafe Lifting practices during dry dock

An unsafe attempt was made to lift 14 empty oil drums using only a web sling, without clamps, certified frames, or proper securing.

Read more
Handling alarms on the bridge – a DP incident

DPO accidentally pressed the adjacent "Take" button on the DP panel.

Read more
Uncoordinated Emergency Shutdown due to pipe failure

All cargo pumps (No. 1, 2, and 3) tripped simultaneously due to Emergency Shutdown (ESD) activation.

Read more
UK HSE: oil company fined after serious failure of elevator

The UK HSE has fined a North Sea oil and gas operator £300,000 after three crew members descended into a water filled lift shaft on a floating platform in the North Sea causing them to become partially submerged.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.