Vessel/Platform Collision – Mooring Bollard Broken by Vessel
- Safety Flash
- Published on 19 March 2018
- Generated on 30 November 2026
- IMCA SF 06/18
- 2 minute read
Jump to:
A platform supply vessel (PSV) approached a platform to deliver the cargo via snatch lift.
What happened?
After starting cargo operations, it appeared that the crane did not have enough boom reach, so the vessel was taken closer to the platform (at around 1 m distance). There were 2m waves at the time.
The vessel’s stern collided with the platform mooring bollard which was damaged. No one was injured. This damage was allegedly not noticed at the time by the crew, and was identified and reported by the client at a later stage.
What went wrong? What were the causes?
Our member notes that this incident happened recently and is under investigation. Detailed information and additional lessons learned, if any, will be communicated at a later date. Our members’ initial findings were as follows:
- Given the unfavourable operational conditions, there was excessive exposure to risk, possibly driven by inadequate planning. The operation should have stopped when conditions were found unsafe.
- Concerns had been raised previously, relating to the absence of fenders and mooring buoys around the platform, and regarding the limited reach of the crane. These had not been addressed. Vessel management should keep their fleet management informed of operational hazards and enable corrective actions with clients and other 3rd parties, as needed.
What actions were taken? What lessons were learned?
Ensure that there is properly documented and agreed guidance available on methods of safely approaching platforms, on escape routes and on go/no-go zones, particularly when new locations are involved.
Related Safety Flashes
-
IMCA SF 23/17
21 September 2017
-
-
IMCA SF 07/17
28 March 2017
-
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.