Incident involving oxy-acetylene cutting

  • Safety Flash
  • Published on 1 August 2001
  • Generated on 24 November 2026
  • IMCA SF 08/01
  • 1 minute read

One of our Members has informed us of recent incident which occurred during the assembly of oxy-acetylene cutting equipment.

An internal explosion occurred and injured a Dive Tender, fortunately not seriously.

The review of the incident revealed the following:

  • Oil or grease contamination in the presence of oxygen probably caused the explosion.
  • A dangerous ‘home made’ manifold of unknown origin had been used.
  • Flashback arrestors were not fitted to the system.
  • Regulators had been removed from the cylinders.
  • The oxygen and acetylene cylinders had not been suitably segregated.

The company involved has proposed the following actions:

  • All hoses and fittings to be thoroughly checked free of oil/grease contaminants.
  • Only use correct approved fittings and hoses in any pressurised gas system.
  • Flashback arrestors must be fitted in the system.
  • Regulators must not be removed from the cylinders.
  • Oxygen and acetylene gas cylinders must be suitably segregated.

The company has also advised its staff to inspect all oxygen and acetylene cutting gear and ensure correct fixtures and fittings in use.

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.