Dropped pallet during forklift operation

  • Safety Flash
  • Published on 18 June 2025
  • Generated on 7 April 2026
  • IMCA SF 11/25
  • 2 minute read

A pallet containing a load weighing 500kg dropped off a flatbed truck in close proximity to a delivery driver.

What happened?

The incident happened during unloading of the flatbed truck, which was carrying two cranes on pallets butted up against each other. The forklift truck operator attempted to offload the first one, but during this operation, the forks accidentally caught the second pallet, causing it to fall off the far side of the truck. At this moment, the truck driver had walked over to the far side of the truck, and the falling load narrowly missed him.

Forklift truck unloading pallet from truck

The fallen load after the incident

What went wrong?

Three causes were identified:

·         The condition of the load - the way the pallet was positioned made it difficult to get a clean lift off the truck, and the high centre of gravity of the load made it easy to topple

·         The forklift truck 

  • The operator did not get off the forklift truck to conduct a pre-assessment of the load or check the fork positioning
  • The forks caught on the pallet behind the one that was being offloaded
  • The forklift truck operator did not stop the job after initial contact when the load appeared to wobble

·         People positioning

  • Lack of communication/instruction to delivery driver on site
  • Delivery driver moved into an unsafe position next to the load

Actions and lessons learned

·         As a result of the incident the company rewrote its own procedures for ‘Safe Use of Forklift Trucks and Mobile Elevating Work Platforms’

·         Ensure with suppliers that cargo and loads are packed and delivered in a safe way

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.