Pedestal Drill Chuck Assembly Detached Causing Head Injury

  • Safety Flash
  • Published on 22 May 2020
  • Generated on 4 November 2026
  • IMCA SF 16/20
  • 2 minute read

What happened?

A crewman was drilling a hole through a wooden plank using a benchtop heavy drill machine in the vessel’s engine room. The drill chuck assembly detached and hit the right side of his forehead resulting in a laceration above his right eyebrow.

A crewman was drilling a hole through a wooden plank using a benchtop heavy drill machine in the vessel’s engine  room. The drill chuck assembly detached and hit the right side of his forehead resulting in a laceration above his  right eyebrow.
A crewman was drilling a hole through a wooden plank using a benchtop heavy drill machine in the vessel’s engine  room. The drill chuck assembly detached and hit the right side of his forehead resulting in a laceration above his  right eyebrow.
A crewman was drilling a hole through a wooden plank using a benchtop heavy drill machine in the vessel’s engine  room. The drill chuck assembly detached and hit the right side of his forehead resulting in a laceration above his  right eyebrow.

What went wrong?

Our member’s investigation noted that:

  • The bench top drill was not fit to use, as the spindle sleeve was not available.
  • There had been an unauthorised modification of the drill chuck assembly (spindle sleeve) – a hexagon headed bolt was modified for use as a spindle sleeve.
  • The injured person and the supervisor were not fully aware of the scope of the assigned activities or job requirements.
  • The job should have been stopped but the risk was deemed tolerable. Safety controls were bypassed.
  • No personal protective equipment (PPE) was worn.
  • The injured person was not familiar with the bench top drill assembly, operation or safety precautions and it was his first time operating the machine.

What were the causes?

  • The immediate cause of the injury was the ejection of the chuck assembly along with the modified spindle sleeve from the spindle hole.
  • The root causes were lack of appropriate supervision and lack of a safe system of work – the injured person should never have been allowed near the machine.
  • Causal factors included:
    • risk was seen as tolerable by both the supervisor and the injured person.
    • the bench top drill had not been quarantined to prevent unauthorised use.
    • there had been no appropriate toolbox talk or risk assessment beforehand.

What lessons were learned? What actions were taken?

  • Handmade or modified tools should not be used.
  • Tools and equipment to be inspected for their fitness, and unfit equipment to be isolated – all equipment was subject to further inspection and unfit equipment was removed from the vessel.

Latest Safety Flashes:

Diver injured foot during high pressure water jetting

A diver suffered a foot injury whilst working with high pressure water jetting (HPWJ) equipment.

Read more
High Voltage isolation near miss

There was a high voltage isolation near miss when crew were working on a TMS (Tether Management System).

Read more
BSEE: poorly maintained crane components cause multiple injuries during personnel transfers

BSEE has published Safety Alert 517 relating to poorly maintained crane components.

Read more
Unsafe attempt to transfer between vessels with no gangway

A crew member was observed attempting to transfer between two vessels alongside each other without using an approved gangway or designated means of access.

Read more
Chemical burn injury during maintenance

A crew member sustained second-degree chemical burns while cleaning fuel oil strainers.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.