LTI: fall from height during anchor chain handling operation

  • Safety Flash
  • Published on 17 December 2024
  • Generated on 13 June 2026
  • IMCA SF 24/24
  • 3 minute read

A worker fell through an opening from one deck to another, and was injured as a result.

What happened?

A worker fell through an opening from one deck to another, and was injured as a result. The incident occurred on an AHTS (Anchor Handling Tug Supply) vessel preparing for a pre-lay operation offshore. Three crew members were involved in the operation: the bosun (who was injured) and two ABs. An AB passed the tugger wire to the bosun, who was then supposed to hand it to the other AB standing on the chain road, for him to attach it to the end of the anchor chain. 

“A” deck – the place from which the bosun fell, illustrating the chain he potentially stepped on

“A” deck – the place from which the bosun fell, illustrating the chain he potentially stepped on

According to the CCTV footage reviewed, the bosun put one foot on the chain barrier while passing the wire over. However, as he attempted to move his second leg, he fell through an opening between two chain barriers and landed 2.75m below on the main deck. First aid was administered onboard, and a vessel doctor called for further assessment. The bosun was subsequently transferred to shore for further medical evaluation. He suffered multiple fractures to his right leg and broke a rib.

What went wrong?

·       The injured person placed his foot on an unstable surface (the chain barrier), which led to the fall;

·       There was a lack of proper planning and risk assessment: The specific activities involved were not covered under the anchor handling risk assessment, meaning important considerations, such as safe access to the chain road, were not properly evaluated;

·       There was a lack of focus and hazard perception: The potential risk of falling while stepping over an unstable chain was not understood.

What can be learned?

Our member suggests that this incident highlights several critical areas for improvement in planning and implementation of high-risk activities.

·       Greater care when accessing locations at height – only correct, proper, secure, stable, and purpose-designed platforms and equipment should be used.

·         Better identify potential fall hazards, particularly in areas with open spaces, such as around chain barriers.

·         A more thorough and detailed risk assessment should be made for each step of the operation, thoroughly evaluating all associated risks. All identified hazards and corresponding control measures should be clearly communicated to the crew and verified to be in place before starting work.

·         Better supervision of high risk tasks, particularly when working at height.

Latest Safety Flashes:

Arm injury – need for focus on safe isolation and task control

A worker sustained an arm injury while troubleshooting a malfunctioning garbage compactor.

Read more
Floodlamp causes scaffold board to start smouldering

Workers on the accommodation deck noticed light smoke emanating from a nearby scaffold structure.

Read more
Lamp fixture fire in office cabin

A fire broke out in a ceiling lamp fitting in a cabin on a vessel.

Read more
BSEE: Prevent fires by inspecting cords, plugs and welding leads before use

The United States Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert 515.

Read more
More positive stories

Some more stories of good things happening – what went right.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.