- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Join the global DP Community at the IMCA DP Conference in Amsterdam. 21 and 22 May. Book now
- Register your interest for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands.
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Case study: confined space fatalities due to Hydrogen Sulphide
This is a brief summary of a recent case report on confined space fatalities on board an oil rig during work involving gas sampling/monitoring inside the “spud cans” of the rig.
It is included as a reminder of the danger of Hydrogen Sulphide and as a means to facilitate discussion. The full case study, prepared by Dr Ajit C Kulkarni, of Hyperbaric Solutions, Mumbai, India, can be found here.
What happened
The legs of a jack-up rig were fully retracted and the “spud cans” or feet of the legs were above the water and accessible for man entry. They were dewatered and forced ventilated for two days. A “Gas free”, i.e. no H2S present, “safe to enter” certificate had to be generated before a marine surveyor could enter for inspection. The onboard diving team (three divers and a diving supervisor) were tasked to enter the “spud can” and obtain gas samples. A diver using SCUBA (self-contained underwater breathing apparatus) equipment and a life-line, climbed down a 5m ladder and went into various corners. He was attended by another diver at the bottom of the ladder, also wearing B.A. This diver was visible to the supervisor above. The third diver was a “stand by” diver dressed and ready to intervene – but not yet wearing B.A.
Shortly after starting the operation, the dive supervisor saw the attendant at the bottom of the ladder collapse. On seeing this, the supervisor impulsively climbed down the ladder to assist, without wearing a B.A set. Before he could reach the attendant, he too collapsed. The alarm was raised and the ventilation rate was increased to drive out the “sour gas” from inside the spud can. As soon as this was done, a large quantity of gas emerged out of the narrow opening of the spud can and the “stand by” person was affected and collapsed.
All three persons who entered the spud can died; the “stand by” person“ was resuscitated, evacuated and admitted to intensive care at hospital.
What went wrong
- Cause of death as determined by the Coroner as asphyxia. Circumstantial evidence pointed to inhalation of H2S anticipated in the spud can. Spud can is almost 5 m in height and because of its typical internal construction, has numerous poorly ventilated nooks and corners;
- In addition, there were puddles of mud sludge which contain dissolved H2S. The first person who went inside the spud can stirred up the collected H2S in low areas and also the sludge containing dissolved H2S. Being exposed to this, he became unconscious and collapsed;
- Ventilation exhaust could escape through a single opening only. The attendant who was at the bottom of the ladder was affected by the toxic gas produced and collapsed;
- The supervisor entered the spud can without B.A and collapsed immediately;
- The “Stand by” person, not wearing B.A, was affected by the gush of gas coming out of the opening due to forced ventilation but being in the open, quantity of gas inhaled was much less and this person survived.
Hydrogen Sulphide
Hydrogen Sulphide is a highly toxic, colourless, combustible gas. It has the unmistakable odour of rotten eggs at low concentration. However, the sense of smell is not a reliable warning because exposure to this gas results in paresis of the olfactory nerve very quickly. It being heavier than air, tends to settle down in low lying areas. It is soluble in water and oil, and its presence in the workplace is a serious environmental hazard.
What was the cause
- Incorrect Breathing Apparatus (B.A) – SCUBA diving equipment – was being used;
- This is entirely – and in this case lethally so – inappropriate for use other than underwater. For enclosed space entry, SCBA (self-contained breathing apparatus) should be used; the face mask is gas tight, preventing entry of toxic gas, fumes etc. from entering.The face mask used in SCUBA underwater breathing apparatus is not tight fitting and some water gets inside and equalizes pressure under the mask. If the mask was tight fitting, as the diver descends in water and there is an increase in ambient pressure, the mask will squeeze the face.
- The two kinds of face mask look similar but are fundamentally different. [IMCA notes: there is a human factors lesson there for us all]
- The team doing the job were not trained for the job and had no idea of the risks involved;
- There was no risk analysis of the job, no tool box meeting was held, no contingency plan prepared;
- The team doing the job were third-party contractors and were not inspected, audited or checked when they arrived on the rig.
Possible solutions identified by author
- Proper planning and appropriate training for enclosed/confined space entry, particularly for third-party contractors;
- Such training should include:
- Active monitoring for H2S gas, including both personal and area monitoring;
- Understanding of the dangers of H2S and how it behaves;
- Where to wear personal detection monitors, preferably over the chest pocket or on the collar, i.e. as close as possible to the nose;
- Proper use of correct breathing apparatus;
- Use of the “buddy” system;
- Training and drilling of emergency response team;
- Proper use of Permit to Work system and safe systems of work;
Members may wish to refer to:
Safety Event
Published: 27 November 2023
Download: IMCA SF 27/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.