Confined space incident
We have recently learnt of a tragic incident involving confined space entry. The two individuals were assigned to de-ballast 12″ of water from a tank on a cargo barge. This entailed opening the hatch cover an accessing the tank to position the pump suction hose in the water. The foreman who entered first collapsed. The rigger, on seeing his colleague had collapsed, entered the tank to rescue him. The alarm was subsequently raised and both the individuals were recovered by personnel wearing breathing sets. Tragically they were found to be dead. The cause of death was oxygen deprivation. The atmosphere immediately above the water level was found to contain no oxygen.
There was a confined space entry permit procedure in place and the procedure was mandatory where confined space entry was necessary. No reason was found as to why the foreman elected to enter the tank on this occasion as he was familiar with the procedure and had used it a few days before.
The company involved has modified its procedure to require on all confined space work that the atmosphere in confined spaces be tested regardless of whether entry is necessary or not.
Safety Event
Published: 1 September 2000
Download: IMCA SF 05/00
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.