Davit failures
What happened?
A member reports two recent issues relating to the davits of small boats:
- During routine inspection of the rescue boat equipment and davit swing, it was noted that the davit would not swing out. This was due to a malfunctioning hydraulic pump not building up pressure;
- During a weekly technical inspection of lifeboats and davits, a delay in response of the aft davit was noticed whilst swinging in the starboard lifeboat to the stowed position. After a few unsuccessful attempts, the hydraulic accumulator valve of the forward davit was changed over to ‘evacuation mode’ in order to direct hydraulic oil to the hydraulic cylinder of the aft davit only. After that, the aft and forward davits came back to the stowed position at the same time.
What went wrong?
- In both cases equipment failure.
- The faults were observed in routine planned inspections of the equipment, which emphasises the importance of conducting inspections and planned maintenance.
Members may wish to refer to:
Safety Event
Published: 4 September 2019
Download: IMCA SF 21/19
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.