Failure of fall wire – update to safety flash 05/11
Members will recall that the UK Marine Accident Investigation Branch (MAIB) published Safety Bulletin 1/11 regarding the failure of a fall wire which caused a rescue boat to fall into the sea, with a subsequent fatality.
Following further findings regrading this incident, the UK MAIB has published a second Safety Bulletin 2/11 (attached) on this incident. The failure of the fall wire was the result of the malfunction of a proximity switch. The incident occurred as the rescue boat reached its stowed position on the davit following a monthly drill. Hoisting was not stopped before the davit reached its stowed position. The proximity switch, that should have cut electrical power to the winch motor before the davit reached its stops, failed to function. The rescue boat and its four crew members fell nearly 29 metres into the water below. One of the boat’s crew members had died and two were hospitalised.
Further information can be found at maib.gov.uk/cms_resources/SB2-11.pdf
Safety Event
Published: 28 July 2011
Download: IMCA SF 09/11
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.