Failure of remote control/emergency stop on rescue boat winch
What happened
There was a failure of the winch remote control and emergency stop during recovery of the rescue boat to the davit. The incident occurred on completion of rescue boat testing in good weather. The personnel in the small boat were disembarked at sea level and used a ladder to access the main deck. The AB started recovery of the boat using a remote control. When close to the final stowage position the remote control failed and the limit switch did not activate as designed. The main power supply switch was then operated to isolate the power supply to the winch.
What went wrong/what were the causes?
Testing revealed that the control circuitry for davit recovery was fully operational. However, the recovery was not automatically stopped by the limit switch. On inspection and disassembly of the contactor, it was found stuck, with contacts in the closed position. The system had undergone annual inspection by an approved independent inspector three weeks previously with the following notes:
- Remote control checked all OK.
- Davit fall wire sheave inspected.
- All electronics checked and found OK.
The most probable cause of failure was frequent intermittent use of the winch for fine adjustment of boat level to make it easier for crew to get into and out of the fast rescue craft. The davit winch was being repeatedly switched on and off for very short time intervals, which can cause the contacts to burn out.
Actions/lessons learned
- Ensure correct retrieval procedure is practiced by all winch operators – limit switches should not be relied on to stop the recovery of craft;
- Confirm correct installation of components including limit/proximity switches for davit systems.
- Where limit/proximity switches have noted systems faults, inspection should be completed before further use;
- Ensure planned maintenance system covers regular function testing of emergency stop switches;
- Limit/proximity switches found to be at fault should be replaced. Replacement switches are not high cost items.
Members may wish to refer to:
- Marine Safety Forum: two incidents relating to fast rescue craft
- Fire-fighting water jet hits antenna – Failure of limits, stops and safeties
- Dropped object near-miss: Falling crane block [The rig crane’s limit switches/stops were apparently not fully operational, thereby allowing the hook block to be heaved all the way up to the boom ]
Safety Event
Published: 11 February 2021
Download: IMCA SF 05/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.