Fatal accident involving a boom crane
A recent incident has been reported to IMCA. The 350T/96m long boom of a derrick lay barge (DLB) 2500 short tonne revolving crane broke, crashed onto the deck, fell into the sea, dragging a lot of debris with it and killed a diver working on the sea bed.
The crane was stationary with its boom in a forward position over the DLB deck at an angle of 45°. There was no load on the main hoist which was in a secured rest position. The DLB was anchored on a northerly heading and the sea condition had two metre swells heading east.
The boom failure was caused by the side force due to the rolling movements which ruptured the coupling studs of the boom foot bearings.
It is believed that the incident could have been avoided by adherence to good maintenance/inspections, working practices and to the operating limits of the crane.
Safety Event
Published: 1 May 1998
Download: IMCA SF 03/98
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.