- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Finger trapped and injured whilst moving hatch covers
What happened?
An AB sustained a serious finger injury when his finger was trapped while attempting to secure a forecastle hatch whilst securing the area following a mooring operation.
What went wrong?
The hatch being secured was heavy and in such a position that it required the AB to reach or climb up to open, close and secure it; this awkward arrangement resulted in finger entrapment.
The task was a common one using equipment from the vessel’s original design and build, and therefore the arrangement had not been questioned. The hazard had not been adequately covered in the task risk assessment, and not reported to vessel management as a safety concern.
What actions were taken?
Our member made the decision that due to the weight, arrangement and position of the hatch being unsafe for handling, it would not be used for mooring operations and a temporary alternative arrangement put in place for running lines. Engineering solutions available:
- Fitting a motion damping strut, such as a fluid-filled gas strut;
- Or, fitting a hatch in a different position that allows for safer handling and improved safety and ergonomics for passing lines.
In addition, hazard hunts conducted to identify other similar issues that may be present around the vessel.
Members may wish to refer to:
Safety Event
Published: 22 November 2019
Download: IMCA SF 27/19
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.