Flood light dropped to deck – corrosion
A floodlight weighing about 6kg was found on the deck, near to the scaffolding storage area, underneath the main crane boom rest. The flood light affixed to the main crane boom rest dislodged from its frame and dropped to deck, a distance of 4.5m. The electrical supply to the flood light fitting was immediately isolated.
At the time of the incident there were no personnel in the area.



What went wrong?
- Hidden corrosion: The flood light mounting frame which remained affixed to the main crane boom rest, showed excessive wear and tear, and had completely corroded, leading to the flood light detaching from its mounting frame;
- There was no secondary retention;
- The flood light had not been identified as a potential dropped object;
- The advanced deterioration of the mounting frame was obscured by the paint work;
- Environmental conditions including vibration, humidity, wind loading, and sea salt corrosion may have impacted the mounting frame materials.
Actions
- Think carefully about what could become a dropped object – perform dropped object surveys
- Consider cross-departmental “hazard hunts” for drop hazards – get some “fresh eyes” in to spot what you may have missed;
- Ensure that everyone knows who is responsible for doing dropped object inspections;
- Make use of secondary retention where appropriate.
Members may wish to review:
Safety Event
Published: 20 May 2021
Download: IMCA SF 14/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.