- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Join the global DP Community at the IMCA DP Conference in Amsterdam. 21 and 22 May. Book now
- Register your interest for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands.
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
High potential near miss: AB slipped over the side during mooring operations
What happened
During mooring operations, an Able Seaman (AB) jumped from the vessel to the quayside to receive the mooring ropes. In doing so he slipped over the bulwark and fell over the side into the sea from a height of 1.75m. At that time, the gap between the vessel and the quay was 0.5-0.6m.
While falling, he managed to grab the vessel fender with his hands, keeping the upper part of the body out of the water. The vessel Master had a direct line of sight to the incident; he immediately stopped the engines and manoeuvred the stern away from the quayside using the bow thruster. This prevented the AB from being crushed between the vessel and quayside as well as from being drawn into the propeller.
He was helped back onto deck by a colleague and after a check-up it was confirmed that he appeared to be unharmed. Nevertheless, he was sent to a medical facility on the same day for proper examination which verified his fitness for work.
What went wrong? What were the causes?
- Procedures not followed: By jumping from the vessel to the quay, the crewman violated existing written procedures. All other persons present were aware that this practice was forbidden, and were aware of the possible consequences, but no one stopped him;
- Shortcuts: The vessel Master did not ask the Port Authority for assistance due to alleged issues experienced in past, where this assistance was either not provided or was provided with a significant time delays. As a result, a shortcut was taken by the vessel crew, which resulted in the incident;
- Routine acceptance of risk/complacency: It was concluded by the investigation team that the unsafe practice of jumping from the vessel to the quayside had developed over time without being confronted or stopped by management.
Lessons learnt
This was a high potential near miss incident which could have been avoided if assistance was requested by the vessel Master from onshore. This incident could easily have resulted in a fatality, and serves as another reminder that shortcuts and deviations from established procedures and safe working practices are not acceptable.
Members may wish to refer to the following incidents:
Safety Event
Published: 23 January 2018
Download: IMCA SF 02/18
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.