Kirby Morgan SL 17C partially detached from neck dam
A member has reported that, following the investigation into a recent incident where a diver’s hat (Kirby Morgan SL 17C) became partially detached from the neck dam, the contractor involved concluded that, rather than the securing pins becoming displaced during the dive, in all probability they were not secured at the beginning of the dive and that the fault lay with the checking and confirmation process rather than with the hardware.
Members are reminded that human errors cannot be eliminated and that robust checking, confirmation and supervising processes need to be in place to prevent these human errors becoming single point failures.
In particular it should be ensured that:
- The roles and responsibilities during any pre-dive ‘dressing in’ checks are clearly defined and all the personnel involved are clear regarding their individual roles and responsibilities;
- Dive supervisors give their full attention during the checks and, if necessary, temporarily suspend any parallel work to ensure the appropriate level of supervision is applied;
- Checklists are used ‘actively’ – that is, the person in charge (dive supervisor) reads out the appropriate checks, one at a time; the person carrying out the checks (diver/bellman/tender) completes the checks and confirms this back to the person in charge, also one at a time, who records that the check has been carried out;
- The diver who is being ‘dressed in’ should carry out a cross-check to help eliminate the potential for single point failure. In the specific case of the SL 17C, the diver can confirm by touch that the neck dam and yoke are in place and also that the pins are in the latched position (i.e. the pins cannot be rotated).
Safety Event
Published: 25 February 2011
Download: IMCA SF 02/11
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.