MSF: Air cylinder failure in lifeboat
What happened
There was a structural failure of an air cylinder fitted in a lifeboat. It occurred without warning. No work had or was being conducted on or around the air cylinder. Three crew members working nearby were injured by the blast debris.
First aid treatment was provided onboard by the medic and they were then sent onshore that night for assessment by a local hospital, and later released.
What was the cause?
The MSF notes that investigation into this incident is currently ongoing. This event – which occurred in July 2020 – was first brought to IMCA’s attention last year. At that time there was insufficient information available to warrant its use in a Safety Flash. See here for the MSF Safety Alert 21-01.
Two preliminary suspected causes of the cylinder failure have been identified:
- Galvanic corrosion between the cylinder material and the metal support frame leading to a weakness in the cylinder wall;
- Cylinders submerged in bilge water for extended period leading to wall corrosion which could have then affected the integrity.
Action
The MSF’s correspondent recommends that such cylinders are:
- Inspected annually for corrosion or wall damage by service providers;
- Hydrostatic [pressure] tested at a required interval of five years.
Members may wish to review also:
- BSEE: Failure of Crane Hydraulic Boom Cylinders
- Failure of fire extinguishers owing to corrosion
- Life raft self-activates and falls to the quayside [cause: gas cylinder was not properly serviced by a third-party service provider]
Safety Event
Published: 17 March 2021
Download: IMCA SF 08/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.