- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
MSF: Unsafe Cargo Transfer Using Pallets
The Marine Safety Forum (MSF) reports in Safety Alert 22-06 that an MSF member reported two separate incidents during deck cargo transfer operations involving pallets.
What happened
Incident #1: Lifting strops were passed through the side of the pallet (See red arrows in diagram) allowing the tension to be placed on the deck boards. The load weighing approximately 150kg was centred on the pallet. The stress on the deck boards allowed them to separate from the pallet eventually failing and allowing the load to fall to the deck.
Incident #2: Loose items were placed on a pallet which was to be loaded onboard. During the lift, the pallet came
in contact with slings attached to a gangway stowed in the immediate area. The contact caused the pallet to shift
allowing a box of copy paper to fall off and fall to deck. Fortunately, there was no-one in the immediate vicinity when the box landed.
What went wrong?
The MSF notes that both incidents were different in nature but did have some similar attributes:
- Task Planning, Risk Assessment and Toolbox Talk did not identify specific hazards associated with the operation;
- There was complacency – a failure to recognize a hazardous situation developing.
![](https://imcaweb.blob.core.windows.net/wp-uploads/2022/04/Screenshot-2022-04-01-150709.jpg)
Lessons
- Pallets have no safe working load (SWL) and have the potential for shifting if the load is not evenly distributed, or if external forces are present during the lifting operation;
- All items being lifted, whether on pallets or otherwise, should be properly secured.
Members may wish to refer to:
- Dropped pallet during loading of stores
- Unsafe lifting operations – potential dropped object (MSF)
- Dropped load (bottled water) during lifting operations
High potential near miss – storage box dropped from forklift
Safety Event
Published: 1 April 2022
Download: IMCA SF 08/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.