- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Near-miss: Failure of diving helmet communications module
A member has reported an incident where the communications module on a Kirby Morgan KM 37 diver’s helmet failed at the interface between the threaded section and the main module. The incident occurred during a dive to 12 msw. The diver was able to reduce the loss of air from his helmet by placing his hand over the partial opening and return to the surface in a controlled manner. The module did not fall out of the aperture in the helmet. There were no injuries.
![Broken helmet communications module](https://imcaweb.blob.core.windows.net/wp-uploads/2014/10/image5.jpeg)
Our member’s investigation revealed the following:
- The module had never been removed from the helmet;
- The helmet had been in storage for several years since purchase with minimal use;
- Water temperature was less than 2°C; Depth: 12 msw;
- No tool marks were found on the securing nut to suggest over tightening.
The failed module was sent to the supplier for inspection and analysis. The supplier inspected the part and performed in-house testing of off the shelf inventory overstressing at worst case levels. It was reported the parts withstood extreme stress tests at elevated and sub-freezing temperatures and passed all inspection criteria. The supplier found that failure of the module appeared to be an isolated case and referred the member to Kirby Morgan Bulletin #1 of 2009.
The following actions were taken:
- Supplier would include, in checklists, that the module should be regularly loosened and retightened during checks, by hand;
- Inspection of all such communications modules -none found with potential failure indications, even in older helmets in more frequent use;
- A recommended inspection/check process was initiated.
Safety Event
Published: 3 October 2014
Download: IMCA SF 16/14
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.