- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Near Miss: Personnel nearly struck by rotating chain attached to flexible pipe
What happened
Crew were involved in the second end transfer of a 4″ (10cm) production flexible up to the top module of the pipelay system. As the second end was being transferred, the tensioners were in the following position: upper tensioner – open, lower tensioner – closed. To allow the weight to be transferred onto the A&R wire the lower tensioners were opened. This then resulted in the production flexible rotating due to the residual torsion that had been built up within the line. A 16.5te chain used for the transfer of the second end was still attached to the pull-in head, as the flexible pipe began to rotate, this chain also spun. Two crew members who were observing the operation were stood nearby and were almost struck by the spinning chain.
![](https://imcaweb.blob.core.windows.net/wp-uploads/2023/04/Screenshot-2023-04-17-093947.png)
![](https://imcaweb.blob.core.windows.net/wp-uploads/2023/04/Screenshot-2023-04-17-094017.png)
What was the underlying cause?
- Key people involved were inexperienced in this specific activity and were not familiar with the task in hand
- There was a failure to identify the risk posed from the chain still being attached to the flexible pipe.
- There was a language barrier:
- Part of the team were unable to speak English;
- The Task Risk Assessment for this operation was only available in English.
- The procedure did not identify when the chain should be removed nor other mitigation measures.
Learnings
- Ensure important documentation such as Task Risk Assessment, procedures and checklists are available in the languages of the crew doing the work;
- Ensure it is specified in procedures or checklists when rigging or any other items are to be attached or removed;
- Always remove the rigging after transferring loads to the A&R; when removal of rigging is not possible, suggest additional mitigation actions in the Task Risk Assessment.
- One mitigating measure was to install a gate with signage restricting access to the top module.
Members may wish to refer to:
Safety Event
Published: 20 April 2023
Download: IMCA SF 10/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.