Near miss: potential dropped object left on top of cargo
What happened?
During deck cargo loading operations from a vessel to an offshore platform, two pieces of unsecured timber were inadvertently lifted from the vessel onto the platform, on top of the lifted cargo – a mud cooler module. This was discovered and reported by the deck foreman on the platform, who immediately informed all involved parties. There were no injuries or equipment damage.
What went wrong? What were the causes?
Investigation revealed that the two timbers were initially placed as dunnage under the lifting frame (“spreader bar”) after loading onto the vessel at the quayside. Third party shore-side stevedores originally placed them to prevent damage to the lifting frame and its slings being caused by movement during the voyage.
When the platform hooked the frame, it was anticipated (by the third-party workers) that the crew would go under the suspended load to remove the dunnage. However, the vessel crew correctly declined to do so and left the timbers in situ. However, the vessel crew did not identify the further hazard left by leaving the timbers on the roof of the mud cooler module.
What lessons were learnt?
In this specific case, a possible solution could have been a pre-lift for repositioning the spreader bar, allowing removal of the timbers by using a hands-off approach, using push/pull poles.
What actions were taken?
- Task risk assessments for lifting operations were reviewed to include risk and controls related to potential dropped objects while handling bulky/heavy loads where cargo lifting frames are used;
- Permit to work checklist was reviewed to include a specific requirement to check for potential dropped object (PDO) associated risks;
The incident, investigation and outcome to be shared with the quayside lifting authority, such that future lifting plans take into account the offshore environment.
Dropped objects from cargo are a significant source of incidents reported to IMCA and to other industry organisations including Step Change and the Marine Safety Forum (MSF).
Members may wish to remind their offshore personnel of the following guidance and promotional material:
Members may also wish to refer to the following incidents:
- Near-miss: Dropped object from cargo
- High potential dropped object near miss: Object fell from cargo
Safety Event
Published: 20 February 2018
Download: IMCA SF 04/18
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.