- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Stored pressure near-miss: Buckle detector expelled from pipe during recovery
A member has reported a near miss incident in which a buckle detector tool was expelled from a pipeline under pressure and landed approximately 2m away. The incident occurred during retrieval of the buckle detector (BD), which weighed approximately 25 kg. The buckle detector came close to two crew members. Had either of them been struck by the tool as it ejected, it could have caused significant injuries.
![Trajectory of BD and point of impact on railings](https://imcaweb.blob.core.windows.net/wp-uploads/2016/07/IMCASF18-16-image1.jpg)
![25kg buckle detector](https://imcaweb.blob.core.windows.net/wp-uploads/2016/07/IMCASF18-16-image2.jpg)
Our member’s investigation revealed the following:
- Back pressure on the buckle detector had not been identified as a risk during the job risk assessment (JRA);
- The task plan did not identify appropriate barriers required for the job;
- The procedure for use of the buckle detector was not risk assessed at the hazard identification and risk assessment (HIRA) stage of the project.
The actions were:
- An ‘all stop’ on buckle detector launch and recovery activities followed by .time out for safety. with all personnel
- An updated task plan to:
- ensure ‘no go’ areas are fully documented
- show means of preventing future recurrence by using a double wrapped sling on the pipe attached to a shackle on the buckle detector cable;
- Ensure plans available of where barriers should be installed to keep people out of the ‘line of fire’ when conducting launch and recovery of buckle detector;
- Consider revision of hazard identification and risk assessment (HIRA) and job risk analysis (JRA) for pipe buckle detection work;
- Consider pipe back pressure as a risk;
- Ensure future buckle detection task plans include clear instructions on where to install barriers;
- Identify other means of launching buckle detector, such as crawler systems which do not require pressurised air.
Members may wish to refer to the following incident (search words: pipe, plug):
Safety Event
Published: 4 July 2016
Download: IMCA SF 18/16
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.