UK HSE: fatal injury following catastrophic failure of pressure test equipment
What happened?
A 64-year-old worker was fatally wounded by shrapnel ejected from testing equipment. He was leak testing eight 1500 litre cylinders, by applying compressed air inside to create pressure. Whilst in the process of venting the air through the test manifold, it catastrophically failed and fatally injured the worker. See the full press release here.
What was the cause?
UK HSE investigation by found that prior to installing the fittings, 1.5 litres of a mineral oil-based corrosion inhibitor had been placed into each of the cylinders. The incident occurred because the inhibitor contaminated the leak test manifold during venting of cylinders and was subjected to enough pressure inside the manifold to ignite and cause the test equipment to fail.
The company was fined £700,000 with full costs of £169,498.82. The HSE inspector noted: “This was a tragic and wholly avoidable incident, caused by the failure of the company to identify any additional risks that arise when work processes are adapted.” [IMCA bold for emphasis]
Safety Event
Published: 19 February 2020
Download: IMCA SF 06/20
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.