US Coast Guard: Wire rope terminations
The United States Coast Guard (USCG) has issued Marine Safety Alert 04-21 relating to wire rope terminations. The Safety Alert addresses the importance of verifying the condition and manufacturing of wire rope terminations used in various systems that utilize wire rope in a load-handling capacity (e.g., lifesaving appliances, cranes, lifting slings).
What happened
The USCG has been investigating a casualty involving a failed wire rope termination that resulted in extensive damage to equipment. The Coast Guard observed that “improperly applied swaged fittings could result in unintentional damage to the wire rope, resulting in failure of the termination. Improper swaging procedure includes failures within a quality management system in which materials are improperly selected and do not match the specifications of the original equipment manufacturer”.
The USCG also made the separate observation that “different types of fittings/end terminations might decrease the safe working load (SWL) of the wire rope. With this in mind, the type of fitting could affect the safety factor that is required by regulation or recommended by industry standard/practice for the application (e.g., 6:1 for lifesaving appliances launched with wire rope falls). As an example, a swaged sleeve in a common turnback eye results in a 90% or better efficiency of the termination (i.e., 10% or less reduction in the SWL of the wire rope) when properly installed in accordance with manufacturer’s recommendations.”
Actions
The US Coast Guard strongly recommends that owners, manufacturers, operators and service providers utilizing wire ropes:
- Visually examine wire rope terminations for abnormalities that may indicate improper installation (Figure 1 shows a crimp with a uniform appearance, Figure 2 shows out-of-roundness, and Figure 3 shows ridges created by over-crimping);
- Compare fitting dimensions against the manufacturer’s specifications/tolerances for the completed fitting (i.e., does the length and diameter fall within fitting manufacturer specifications);
- Verify through documentation related to the manufacturing of the assembly that the materials were properly selected and that the termination type does not reduce the SWL of the wire rope below the minimum safety factor for the type of service.
IMCA notes that over-crimping can also be caused by the incorrect crimping die being used during manufacture. Ensure that all wire ropes and their terminations are inspected by a competent person prior to being used.
Members may wish to refer to:
Safety Event
Published: 11 August 2021
Download: IMCA SF 22/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.