Wrapped cargo slipped during loading and fell
What happened?
A large load weighing over six tonnes was dropped during loading operations. The item was a hot air duct. The centre of gravity (COG) of the load and the lifting points were marked on the tarpaulin wrapping the load and this information was used during the lift. The hot air duct was slightly tilted when lifted but within margins, and loading was continued. Although one person called STOP, this was immediately overruled by a supervisor. When the load was approximately 1.5m above deck and under the control of taglines from the riggers, the lifting sling slid towards the centre of gravity and one side of the load bounced on the deck, while the load was still hanging in the rigging. The rigging was not damaged or broken.
The damaged hot air duct was sent ashore again for repairs. No-one was harmed or injured.
What went wrong?
The centre of gravity of the load and lifting markings were wrongly marked on the tarpaulin, resulting in the sling sliding during loading towards the centre of gravity and thus one side of the air duct bouncing onto the deck.
What were the causes?
Our member noted the following points:
- Wrongly marked COG and lifting points;
- The lift was considered by crew as an engineered lift due to marked COG and lifting points on the tarpaulin;
- Saddles were loose due to poor construction;
- No clear communication – it was unclear who was in charge of the operation; too many people interfered with the lift;
- ‘Stop work authority’ was not followed, and no risk assessment/evaluation was made after the STOP call;
- The tarpaulin didn’t give any friction to the sling or the rigging.
What actions were taken?
- Take care with supplied COG or lifting markings;
- Reiterate/discuss the standard operating procedure, and who will be in charge;
- ‘Stop work authority’ to be reinforced/explained by senior management.
Members may wish to refer to:
- Dropped object – intermediate bulk container (IBC) [centre of gravity shifted during lift]
- Uncontrolled rotation of 9.6m reel [unplanned and unforeseen shift of centre of gravity]
- Fatality during lifting operations[finding: all lifts require planning whether they are ‘routine’ or non ‘routine’]
Safety Event
Published: 13 February 2020
Download: IMCA SF 05/20
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.