DP event investigation and testing inside the 500m zone
- DP Event
- Published on 29 March 2017
- Generated on 14 May 2026
- DPE 01/17
- 1 minute read
Incident
Jump to:
The vessel should have proceeded out of the 500m zone to a safe area prior to investigating the fault and conducting tests.
Comments
The report concluded that the vessel should have proceeded out of the 500m zone to a safe area prior to investigating the fault and conducting tests.
Considerations
- There is no doubt that in circumstances such as this, where investigation and testing is required following a DP event, it should be conducted in a safe location and as a minimum outside the 500m zone.
- The DP system’s level of redundancy always needs to be considered during investigation and testing.
- It is not evident from the report, but it is wondered whether complacency contributed to this bad practice.
- The original reported DP alarm should have resulted in a DP yellow alert.
- The vessel might have considered using the independent joystick (IJS) rather than individual levers.
- Emergency handling of the vessel should be practised on a regular basis.
Latest DP incidents
-
Think twice. Press once!
On a DP equipment class 2 supply vessel engaged in drilling, an incident occurred due to lack of operational knowledge
DPE 01/26
11 May 2026
Incident
-
Network issues, not a thing of the past
A DP equipment class 3 vessel was engaged in saturation diving activities, with two divers in the water when this DP incident occurred.
DPE 01/26
11 May 2026
Incident
-
All swept up
A DP equipment class 2 vessel was engaged in rock placement operations, within close proximity to a structure, when this event occurred.
DPE 01/26
11 May 2026
Undesired event
-
Hybrid system won't accept load
A DP equipment class 2 vessel was engaged in operations whilst holding position on auto DP, when this undesired event occurred
DPE 01/26
11 May 2026
Undesired event
-
DP drill scenario – Loss of main DP system UPS
The objective of this scenario is to identify risks and impacts of losing the main DP system uninterruptible power supply, possibilities to reduce that risk and suitable actions to be taken if such an occurrence happened.
DPE 01/26
11 May 2026
Drill Scenario
The case studies and observations above have been compiled from information received by IMCA. All vessel, client, and operational data has been removed from the narrative to ensure anonymity. Case studies are not intended as guidance on the safe conduct of operations, but rather to assist vessel managers, DP operators, and technical crew.
IMCA makes every effort to ensure both the accuracy and reliability of the information, but it is not liable for any guidance and/or recommendation and/or statement herein contained.
Any queries should be directed to DP team at IMCA. Share your DP incidents with IMCA online. Sign-up to receive DP event bulletins straight to your email.