Aluminium fresh water tanks: Near collapse due to serious corrosion

  • Safety Flash
  • Published on 1 January 2002
  • Generated on 23 November 2026
  • IMCA SF 01/02
  • 2 minute read

During an owner’s annual inspection, serious corrosion attacks were found in integrated aluminium fresh water tanks, which required extensive repair.

What happened?

Brackets and stiffeners were found partly corroded through, as shown in figures 1 and 2. The corroded areas in the fresh water tank had to be partly renewed and repaired to an acceptable standard.

Transverse bulkheads and deckhead

Transverse bulkheads and deckhead

Bottom plating

Bottom plating

Probable Cause

The process for cleaning the fresh water tanks was considered to have been a major factor in the corrosion process. The fresh water tanks were sterilised annually, which exposed the tanks to a solution of hypochlorite for 12-24 hours. In addition, the shore-supplied water was frequently chlorinated, which meant that the tanks were frequently exposed to chlorides.

Even small amounts of hypochlorite can be very dangerous for aluminium, irrespective of the Al-alloy chemical composition, resulting in the development of serious pitting. Once pitting corrosion has started, it may continue to develop for a certain period if the tank is not properly washed with water after the application of hypochlorite. The filling and emptying of the tank is not sufficient to remove all the corrosion products. The reason for the corrosion attack is considered to be that the thin aluminium film on the surface is depolarised and locally broken down, in connection with the formation of chlorine released from the hypochlorite.

Lessons to be Learned

  • Hypochlorite or other chloride-containing chemicals should not be used for sterilisation of aluminium fresh water tanks if the tanks have not been fully coated.
  • In the case of uncoated aluminium fresh water tanks, other means of sterilisation than chloride-containing chemicals is needed, e.g. by using ultra-violet light.
  • If hypochlorite is used in coated tanks, it is essential that the tanks are thoroughly cleaned after the process. This is to minimised the change of corrosion occurring in the event of the coating breaking down.

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.