We have received a report of an incident on one of our members’ vessels where a Simrad SHT SPT 319 transponder was retrieved from the seabed.

What happened?

Once on deck and during the opening procedure of the housing, to enable the batteries to be checked, there was a build-up of internal pressure. This caused an explosion of the internal casing resulting in flying debris and the subsequent formation and release of possibly toxic gases. Fortunately no-one was injured in this incident.

Recommendations

The contractor involved has advised its personnel to treat all transponders with care and if there is any doubt about any unit it should be put in safe quarantine until expert help is arranged. They advise that Simrad’s operations manual should be referenced for safety guidelines.

Latest Safety Flashes:

Bunker hose obstructing emergency exit

A bunker hose was discovered routed in a way that partially obstructed the stern emergency exit hatch.

Read more
Watertight door and emergency hatch found open at sea

Watertight doors and an emergency hatch were observed open in the ER (Engine Room) during an offshore audit.

Read more
ATSB: Undocumented modification contributed to steam burns

An unplanned pressure release resulted in burn injuries to three crew members.

Read more
Smoke in the battery room

Smoke was observed in the battery room of a vessel alongside.

Read more
Hull crack arising from vibration

A small vessel built of aluminium experienced vibration coming from the propeller.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.