Failure of moonpool railing system caused man overboard situation in moonpool

  • Safety Flash
  • Published on 28 April 2026
  • Generated on 16 November 2026
  • IMCA SF 08/26
  • 4 minute read

A crew member was working in the moonpool area when they lost balance and fell in but managed to grab hold of the guidewire, preventing an uncontrolled fall into the sea.

What happened?

A crew member was working in the moonpool area when they lost balance and leaned against a removable railing section intended to act as a primary safety barrier. The railing post failed, causing the gate to swing inward toward the moonpool. They fell into the moonpool but managed to grab hold of the guidewire, preventing an uncontrolled fall into the sea. They gradually slid down the guidewire until reaching the guidewire weight, at water level inside the moonpool.

Co-workers intervened immediately, raised a man overboard alarm, and using a boathook pulled the crew member to safety. The crew member was recovered within 52 seconds of the initial fall. The crew member sustained a dislocated shoulder and was transported to hospital for treatment.

What went right?

Crew reaction was immediate and effective. Crew worked as a team, using clear communications, and the rescue was made quickly with available tools. Emergency response procedures were followed, and medical support was provided without delay. These actions prevented a potentially fatal outcome.  

What went wrong?

  • The removable railing and gate system were not included in the structural inspection or maintenance programs, leading to unnoticed deterioration over an extended period.
  • Organizational responsibilities for maintaining and inspecting removable barriers were unclear.
  • The railing was being relied upon as a primary safety barrier, but its condition had not been verified before use.
  • There was no task guidance/procedure for work close to removable barriers.
  • Previous observations from crew members about railing condition had been reported but were closed without appropriate actions because the reporting and follow-up process did not ensure that the concerns were properly captured, understood or escalated.

It is to be emphasised that the person involved was performing their work correctly and that the root causes were systemic, related to design, inspection, communication, and structural integrity management.

What was the cause?

The immediate cause of the railing post failure was advanced structural degradation, leading to the gate opening unexpectedly when the post detached at deck level. The degraded condition of the barrier was not identified.

These root causes were identified:

  • Inadequate design/material selection: Dissimilar metals were not evaluated for long‑term use in the marine environment; no secondary securing mechanisms.
  • Inadequate inspection and monitoring: Removable railings not included in structural inspection programs.
  • Inadequate communication between organisations: No clear ownership between vessel owner and operator for barrier inspection and integrity.
  • Procurement/technical specifications not aligned with operational use: Guidewires delivered outside expected operational characteristics (stiffness/lubrication).
  • Inadequate development of procedures: No documented process for tasks performed near unsecured or removable barriers; hazard not captured in pre task risk assessments.
  • Reporting system: Hazardous conditions were documented, but not escalated with actionable follow-up. 

Lessons to learn

  • Structural barriers (railings, gates, removable posts, gratings, hatches) should be treated as structural safety-critical elements and included in formal inspections and preventive maintenance systems.
  • Assess compatibility of materials – be particularly careful with dissimilar metals in the marine environment.
  • Ensure there is clearly understood “ownership” and responsibility for maintenance of structural integrity.  
  • Ensure hazard reports have verifiable, actionable, documented  follow‑up.
  • Removable barriers should have secondary locking mechanisms and should be positively secured prior to use.
  • Pre-task risk assessments should take into account the possibility of barriers failing, and include checks of physical protection measures.
  • When things DO go wrong and barriers DO fail, there’s no substitute for the team being prepared: Emergency preparedness and teamwork can significantly reduce the severity of an incident.

Members may wish to refer to

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.