SOPEP oil booms

  • Safety Flash
  • Published on 1 November 1999
  • Generated on 15 November 2026
  • IMCA SF 06/99
  • 1 minute read

One of our Members has alerted us to a problem with one type of SOPEP oil boom – type SMB40.

SPOEP oil booms are normally manufactured using blown polypropylene as the absorbing membrane, contained within an outer cover manufactured and sewn together using polypropylene. Whilst polypropylene will begin to melt at 160°C, it will not support combustion.

Type SMB40 oil booms have been found to be covered in nylon, which will burn rapidly when in contact with an ignition source.

The member involved has instructed all of its vessels to remove these booms from service and has informed us that the manufacturer has withdrawn this type of boom from offshore sale and use.

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.