Incompatible threads on the bell onboard gas bottles
- Safety Flash
- Published on 2 December 2000
- Generated on 28 November 2026
- IMCA SF 08/00
- 1 minute read
We have received a report from a diving support vessel (DSV) that during the re certification and testing of the bell onboard gas bottles, it was found that the pillar valves were incompatible with the threads on the bottles.
The bottles were W28.8 x 1¼” according to DIN 477. The pillar valves were ¾” NPT.
Since it is understood that this re-certification was done in the past by a third party test house, contractors may wish to examine their own worksites to check that they do not have a similar problem.
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.