Loss of DP position caused by incorrect gyro heading

  • Safety Flash
  • Published on 21 May 2008
  • Generated on 21 November 2026
  • IMCA SF 09/08
  • 1 minute read

An incident has been reported to IMCA in which a DP Class 2 shuttle tanker lost its position during a DP offtake operation due to sudden and simultaneous loss of all position reference systems.

What happened?

 Investigation disclosed that loss of DP position reference systems was directly caused by incorrect gyro heading, corrupting all offset calculations in the DP model.

Root cause of incorrect gyro heading was found to be erroneous GPS signals to all gyros over a short period of time.

A corrective action in the form of more stringent criteria for acceptance of position reference systems into the DP has already been established.

Furthermore the gyro manufacturer is about to upgrade the software to include rejection of erroneous GPS latitude/speed compensation data.

Dual gyrocompass system

Dual gyrocompass system

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.