Dropped object during crane operations

  • Safety Flash
  • Published on 30 March 2021
  • Generated on 28 November 2026
  • IMCA SF 09/21
  • 2 minute read

A piece of timber weighing 7.6 kg fell approximately 10 m from a crane jib and landed on the main deck.

What happened?

A  piece of timber fell from a crane jib and landed on deck. The main crane on the vessel was being prepared for lifting operations by four deck crew and the crane operator. 

When the crane hooks were disconnected, the deck crew moved clear to allow the crane operator to start luffing the jib from the cradle. 

As the jib was slewing around, the crane operator observed an object fall from a height of approximately 10 metres to the main deck.

No-one was nearby – the nearest crew were 15 m away from where it landed. 

The dropped object was identified as a piece of timber, weighing 7.6 kg. This had been used in a temporary repair of the dunnage on the boom rest.

Main crane and boom rest

Main crane and boom rest

Section of timber after dropping onto the deck

Section of timber after dropping to the deck

What went wrong?

  • Initial design did not sufficiently address the lateral movements of the jib in the boom rest.

  • Responsibility for the crane and associated equipment was not clearly understood.

  • The temporary repair:

    • Several onboard inspections and third-party inspections were conducted which did not identify issues with the support dunnage and subsequent temporary repairs.

    • The damaged wooden packer was formally reported nearly a year earlier. This report had been closed out prematurely when a temporary repair was made.

    • The temporary repair was put in place using screws rather than bolts to attach a board over the damaged wooden packer. The screws corroded, causing the board to become loose and fall to the deck.

    • A work order had not been created for remedial works on the damaged support timbers.

  • There was no checklist developed to include inspection of the boom rest.

Actions

  • Ensure roles and responsibilities are clearly defined, communicated and understood.

  • Review all lifting appliances, supports and cradles. Ensure that the equipment is maintained in its as built condition.

  • Confirm that the boom rest is part of the vessel planned maintenance system.

  • Ensure crane inspection checklists include inspection of the boom rest.

  • Confirm areas around crane boom rests are included in hazard hunts for potential dropped objects.

Members may wish to refer to:

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.