The UK Health and Safety Executive (HSE) has prosecuted a company after an electrician died in a fall of approximately eight metres when an access panel on the raised walkway of an overhead crane gave way beneath him.

What happened?

An electrician was repairing wiring that had been causing a short circuit on the lifting equipment of a large overhead gantry crane. As he was walking along the crane’s walkway, an access panel gave way beneath his feet, causing him to fall through to the ground below. He sustained fatal injuries and was pronounced dead at hospital.

Photo of crane platform

What went wrong?

HSE investigation found the company had failed to maintain the crane walkway’s access panels, which had been used to replace lighting fittings some months earlier. Also, the panel itself had been subject to weld repair, and there was no evidence of any steps being taken to ensure that the panel was safely replaced into the void and secured to ensure it did not fail.

Speaking after the hearing, the HSE inspector said that workers “were at risk from serious injury whilst walking on a gantry 26 feet high, as the company had failed to assess the risk of these access platforms, which should be secured in accordance with the manufacturer’s instructions.”

The inspector noted that “This was an incident, which could easily have been prevented had the company considered the risks associated with such access panels not being secured in place following maintenance work and general wear and tear.”

Latest Safety Flashes:

Dropped GRP cover during subsea lifting

A vessel was lifting and relocating a Pipe Line End Manifold (PLEM) GRP Top Cover when the load became detached and dropped approx. 7m.

Read more
Umbilical support frame made contact with passing vehicle on public road

Whilst travelling, a contractor transporting umbilical support frames (USFs) made contact with a passing vehicle as one of the frames dropped down.

Read more
Petrol driven equipment left stored in an emergency generator room

Stored snowblower created an unnecessary fire and explosion risk, as well as blocking access around critical equipment.

Read more
Mechanic got burns due to fire in portable generator

During refuelling, petrol (gasoline) spilled around generator and ignited.

Read more
Some positive findings and good practices

Collection of some positive findings and good practices.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.