UK HSE: worker died following fall from crane platform

  • Safety Flash
  • Published on 8 April 2022
  • Generated on 28 May 2026
  • IMCA SF 09/22
  • 2 minute read

The UK Health and Safety Executive (HSE) has prosecuted a company after an electrician died in a fall of approximately eight metres when an access panel on the raised walkway of an overhead crane gave way beneath him.

What happened?

An electrician was repairing wiring that had been causing a short circuit on the lifting equipment of a large overhead gantry crane. As he was walking along the crane’s walkway, an access panel gave way beneath his feet, causing him to fall through to the ground below. He sustained fatal injuries and was pronounced dead at hospital.

Photo of crane platform

What went wrong?

HSE investigation found the company had failed to maintain the crane walkway’s access panels, which had been used to replace lighting fittings some months earlier. Also, the panel itself had been subject to weld repair, and there was no evidence of any steps being taken to ensure that the panel was safely replaced into the void and secured to ensure it did not fail.

Speaking after the hearing, the HSE inspector said that workers “were at risk from serious injury whilst walking on a gantry 26 feet high, as the company had failed to assess the risk of these access platforms, which should be secured in accordance with the manufacturer’s instructions.”

The inspector noted that “This was an incident, which could easily have been prevented had the company considered the risks associated with such access panels not being secured in place following maintenance work and general wear and tear.”

Latest Safety Flashes:

Worker suffered crush injury while handling unstable steel plates

Steel plates suddenly toppled over to the side trapping a worker's left hand and wrist between a frame and an emergency stop pedestal.

Read more
High Potential Near Miss: Dropped object due to contact with crane sheave

A Dynamic Positioning (DP) beacon came into contact with sheave protection bars, resulting in the beacon and its holder assembly detaching and falling to the deck below.

Read more
Machinery damaged through improper maintenance technique

During an audit on an offshore vessel it was observed that the fuel oil purifier failed to self-discharge.

Read more
Shifting cargo and deck spill during heavy weather

A sodium chloride brine storage tank shifted approximately 0.5m during heavy weather conditions.

Read more
MSF: Fast Rescue craft (FRC) washed overboard and lost at sea

The Marine Safety Forum (MSF) has published Safety Alert 26-03 relating to the loss of a Fast Rescue Craft (FRC).

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.