Diver reports unwell post-dive: non-decompression illness

  • Safety Flash
  • Published on 14 August 2025
  • Generated on 19 November 2026
  • IMCA SF 14/25
  • 2 minute read

A diver experienced a dizzy spell about one hour after completing a diving operation

What happened?

The incident occurred after the 50 year old diver undertook a dive to 87 feet with a bottom time of 31 minutes. The diver was decompressed on a USN rev 7. 90/33 'freetime dive’ and reported well upon surfacing. About one hour later, on deck, the diver called out for attention reporting extreme nausea and dizziness. 

What was the response?

The diver was immediately recompressed in the chamber on a USN treatment table 6 as per company procedure with a Diver Medic Technician (DMT) with him in attendance. The DMT performed a full physiological and neurological examination and blood sugar levels were taken as a precautionary measure. The diver’s blood sugar levels were observed to be dangerously high.

A hyperbaric physician was contacted and following their advice, decompression illness was ruled out and hyperglycaemia was suspected, as the examination pointed towards a diabetic response. Treatment table was switched to a Table 5 to reduce chamber time so that the diver could have his blood sugar levels brought under control at the earliest opportunity.

After 90 minutes the diver and DMT were able to leave the chamber. The diver was evacuated ashore for further medical attention. 

What was the problem?

It was later reported that the diver had an unreported diabetic condition for which he was not taking any traditional therapy but was seeking alternative natural methods.

What were the recommendations?

  • Healthy eating ‘campaign offshore’ & Welfare Improvement
    • Crew should engage with vessel medics for nutritional advice.
    • Crew should be motivated to declare medical issues before coming offshore.
    • Crew need to be confident that their jobs are not at risk because of declaring their medical conditions.
  • Improve crew education on common non-communicable diseases like Diabetes and Hypertension so that they can easily spot when they have symptoms.
  • Encourage use of gym when offshore – physical and mental fitness needs to be encouraged and looked after.
  • Look closely at ensuring how divers maintain their fitness and Body Mass Index (BMI) to an acceptable level.

Members may wish to refer to:

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.