Injured finger during cargo operations

  • Safety Flash
  • Published on 27 July 2018
  • Generated on 19 November 2026
  • IMCA SF 16/18
  • 2 minute read

During cargo operations, a crewman got his finger stuck between the cargo and the lifting chain.

What happened?

The incident occurred when a vessel was discharging modules with a weight of 220 tonnes direct from the vessel to a trailer on the quay. One hook of a chain tackle which was connected to the cargo, fell off. The other hook was still connected to the trailer. When reconnecting the hook that fell off, a sudden movement of the module meant that one finger got stuck between the module and the chain. When the module swung back the crewmember was able to remove his hand. His finger was seriously damaged, and he had to be sent to hospital for X-ray and stitches. He came back onboard some hours later.

Our member noted:

  • The lifting was taking place at a relatively unsheltered location; there was some vessel movement from swell, but this was considered to be within acceptable limits.
  • The crew were experienced in this discharge operation; it was second time the ship was discharging in this port.
Crewman got his finger stuck between the cargo and the lifting chain

What went wrong? What were the causes?

  • There had been a change of plan, for which there had been insufficient management of change (MoC). The company has a technique for use in exposed harbours where swell is an issue. It was felt that there was insufficient equipment available for that technique to be used safely, so the decision was made to land the cargo straight on the trailer, using chain tackles to reduce the horizontal motion.
  • No job hazard analysis or toolbox talk took place for the alternative lifting technique; this is considered to be the cause of the incident.

What actions were taken?

  • New technique was to be developed for landing cargo in a swell port, based on tools/equipment the company used in another product group (cross learning).

Members may wish to review:

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.