High potential near miss: Slip on tag line during crane operations

  • Safety Flash
  • Published on 23 August 2017
  • Generated on 17 November 2026
  • IMCA SF 21/17
  • 3 minute read

The Marine Safety Forum (MSF) reports an incident in which a crewman slipped and fell during lifting operations.

The Marine Safety Forum (MSF) reports an incident in which a crewman slipped and fell during lifting operations

What happened?

The incident occurred when a vessel was preparing for cargo transfer to an offshore installation. Two crew were on deck ready to hook a load onto the installation crane. A tag line was attached to the load. As the load was hooked on, one of the seamen was seen to fall to the deck. Crane movement was stopped; the seaman got back on his feet and was uninjured.

The MSF notes that this near miss had a high potential for serious injury:

  • The crane could have lifted the load and it could have collided with the seaman when he had fallen.

  • The crane could have lifted the load and the tag line could have tightened around the seaman’s leg lifting him off the deck.

What went wrong? What were the causes?

After hooking on, the seaman had hold of the middle part of the tag line, and took a step back. He stood on the tag line, tripped and fell.

The MSF notes that industry guidelines (Guidelines for Offshore Marine Operations (GOMO)) state that the use of tag lines should generally be avoided. However, it is recognised that certain conditions may require the use of them – this operation required the use of a tag line due to the relatively very light and fragile nature of the item being transferred.

The guidelines go on to state:

  • All sections of the line, including slack must be kept in front of the body, between the handler and the load.

  • Where two or more persons are handling the same line, ALL must work on the same side of the line. Any slack must be kept in front of the group.

The MSF alert continues: “It is recognised that utilising tag lines with standard cargo units inherently puts distance between the handlers and tag line due to the dimensions involved. In this case, with a small box to be transferred, the tag line was far closer to the handlers and required further care and preparations to avoid conflict.”

What lessons were learned? What actions were taken?

  • The MSF notes that additional pre-planning should have been conducted:

    • Identify which side of the loads the cargo handlers were to work from and the direction in which they will move away.

    • Run the tag line at the opposite side of the load and in the other direction.

  • The risk assessment for deck cargo operations was reviewed particularly with respect to the use of tag lines. The crew was formally briefed (and a record kept thereof) on the contents of the reviewed risk assessment.

  • Additional training in the use of tag lines, particularly when dealing with small or fragile loads, was carried out.

  • Future operations would be more closely monitored from the Bridge.

Members may wish to refer to the following guidelines:

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.