Worker lost his leg when he was hit by a forklift truck during lifting operations

  • Safety Flash
  • Published on 2 March 2018
  • Generated on 17 November 2026
  • IMCA SF 05/18
  • 1 minute read

The UK HSE reports that an engineering company has been fined after a worker lost his leg from the knee down when he was hit by a forklift truck.

What went wrong? What were the causes?

A worker was seriously injured whilst carrying out a lifting operation involving the transporting and loading of pipe spools onto a flatbed truck. A forklift truck, for which he was acting as banksman, drove into the back of his left heel. His left leg had to be amputated at the knee.

UK HSE investigation found that the company had failed to properly plan, organise and carry out the lifting operation in a safe manner.

The HSE inspector noted: “All lifts must be properly planned, assessed and carried out in a safe manner. There were other safer, reasonably practicable options that the company could have taken to prevent the forklift coming into contact with the individual. The safest method in this instance was to use tag lines or push sticks to control the load, as opposed to controlling the load by hand.”

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.