- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Near Miss – Messroom fridge fell over during rough seas
What happened
During transit through heavy seas, a fridge tore loose from the messroom wall and fell on its side. The incident occurred when the vessel was transiting out to the field and was experiencing 3-4m seas. During one large roll, a tall fridge in the messroom came away from the bulkhead after its primary securing brackets were pulled out of the bulkhead due to the motion of the vessel. The fridge swung on the last remaining fixing before falling on its side.
Although there were personnel in the messroom at the time there were no injuries reported and the potential for injury was unlikely. Minor damage was sustained to the fridge.
![](https://imcaweb.blob.core.windows.net/wp-uploads/2023/04/Screenshot-2023-04-17-094546.png)
![](https://imcaweb.blob.core.windows.net/wp-uploads/2023/04/Screenshot-2023-04-17-094615.png)
The fridge was secured to the deck with cargo straps and later returned to the upright position, inspected by the ships electrician and secured to the bulkhead with alternative suitable fixings.
What went wrong
- Inadequate primary fixings used to secure fridge to bulkhead;
- The strength of the bulkhead construction (a stud wall) not taken into consideration;
- No-one took into consideration, the potential failure of fixings during rough seas.
Learnings
- Could this happen on your vessel?
- Identify and inspect heavy objects in the accommodation areas e.g. galley, gym, etc to ensure that the securing is robust enough to withstand rough seas;
- When securing items consideration should also be given to what these fixings are secured to, in this example the hollow stud wall was not considered when securing the fridge. The fixings are no stronger than what they fixed to!!
- Suitable fixings for hollow/cavity walls should be utilised for fixing equipment e.g. hollow wall anchors.
Members may wish to refer to:
- American P&I Club: Extreme bollard pull [bollards were pulled right out of the ground of the dock]
Safety Event
Published: 20 April 2023
Download: IMCA SF 10/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.