Loss of DGNSS resulted in ROV being recovered
- DP Event
- Published on 2 June 2017
- Generated on 14 September 2026
- DPE 02/17
- 2 minute read
Incident
Jump to:
When considering redundancy of satellite systems do not just consider the manufacturer, but also correction type and transmission method.
Comments
Both the satellite positioning systems in use were from the same provider.
The report recognised this and recommended that the systems were changed so that position information was provided by different service providers.
The service provider informed the operator after the event that its services experienced periods of increased latencies for just over twenty minutes on the day and time of the incident.
Considerations
- It would appear from the information available that the standby hydroacoustic position reference (HPR) system did not have an acoustic transponder on the seabed. In any event it was not utilised.
- Proper consideration should always be made of the required PRS based on the specific operation and the DP equipment class of the vessel.
- When considering redundancy of satellite systems do not just consider equipment manufacturer and software versions; the correction type and transmission method should also be different.
- It is noted that two separate vendors could use correction details from the same source, therefore users should compare what correction type is being used.
- In similar situations users could consider switching to raw global navigation satellite system (GNSS) data, therefore staying on DP but with a larger footprint.
Latest DP incidents
-
Holding position, losing references
While approaching a turret-moored, weather-vaning offshore installation (FPSO), in preparation for cargo operations, a DP equipment class 2 vessel experienced significant rolling of up to 15–20° due to a long-period swell close to the vessel’s natural roll period, resulting in a resonance effect
DPE 02/26
1 September 2026
Observation
-
Know your equipment, or at least where to find the answers
During an update in the Follow Target Mode, the crew noticed an anomaly with joystick control.
DPE 02/26
1 September 2026
Observation
-
A chain of small failures leads to a major consequence
While conducting cargo operations on DP a vessel experienced a partial blackout caused by an unexpected shutdown of generator 3
DPE 02/26
1 September 2026
Incident
-
New equipment, unexpected consequences
During the operation, a loss of DGNSS correction signals was experienced across multiple vessel DGNSS units.
DPE 02/26
1 September 2026
Incident
-
DP drill scenario – Loss of seawater cooling pump redundancy
Exercise scenario – Loss of seawater cooling pump redundancy
DPE 02/26
1 September 2026
Drill Scenario
The case studies and observations above have been compiled from information received by IMCA. All vessel, client, and operational data has been removed from the narrative to ensure anonymity. Case studies are not intended as guidance on the safe conduct of operations, but rather to assist vessel managers, DP operators, and technical crew.
IMCA makes every effort to ensure both the accuracy and reliability of the information, but it is not liable for any guidance and/or recommendation and/or statement herein contained.
Any queries should be directed to DP team at IMCA. Share your DP incidents with IMCA online. Sign-up to receive DP event bulletins straight to your email.