The United States Coastguard (USCG) has published Marine Safety Alert 01-17 relating to a man overboard fatality.

What happened?

Whilst a vessel was at anchor off the coast, a crew member that could not swim was working over the side in a ‘bosun’s chair’ to paint the vessel’s mid-ship draft marks and load lines. Unfortunately, when his shipmates on deck started to haul him back up, the bosun’s chair rope parted and he fell into the water. He survived the fall and attempted to swim towards a life ring that had been thrown to him, but he ultimately submerged and was lost. Other crew members attempted to launch a rescue craft, but it failed to operate.

What went wrong?

This terrible incident is an example of where following safety management system procedures could have prevented a death or injury. Investigators found that the Captain and Chief Mate had met and developed a suitable work plan. This plan was later communicated to the crew involved. The plan had several important elements, including inspecting the Bosun’s Chair and manila rope rigging, and requiring that the crewmember going over the rail wear a personal flotation device (PFD) and use a safety harness and lifeline.

However, the plan was not implemented. Crew members failed to adequately check the strength of the bosun’s chair rope, instead simply pulling on it. Also, the deceased crew member had not been not wearing a PFD, and, even though he wore a safety harness along with a lifeline, the lifeline went untended and was not tied off to the vessel. The vessel’s Bosun was not present, and it remains unknown as to who was supervising the operation. Finally, months before this tragedy, the Chief Mate had placed a requisition request for new manila rope and for PFD work vests that were designed to be worn with the vessel’s safety harness; however, the request went unfilled.

Recommendations

As a result of this casualty, the USCG strongly reminds vessel owners and/or operators and all personnel on board vessels everywhere to do the following:

  • Properly use safety equipment.

  • Ensure adequate supervision of work teams.

  • Develop workplace mind-sets that properly develop and execute plans, including those for worst case scenarios.

  • Implement barriers to prevent such scenarios.

  • Fully implement and adhere to Safety Management System requirements.

The full report can be found at uscg.mil/hq/cg5/cg545/alerts/0117.pdf.

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.