Technical Service Bulletin from Broco/Rankin – BR22 Plus Exothermic Cutting Torch

  • Safety Flash
  • Published on 22 March 2018
  • Generated on 28 November 2026
  • IMCA SF 07/18
  • 1 minute read

The Association of Diving Contractors International (ADCI) has circulated an updated Technical Service Bulletin from Broco/Rankin relating to the BR22 Plus Exothermic Cutting Torch. This was sent out by Broco/Rankin on 13 March 2018.

The bulletin, available here, notes that “a recent report of an external oxygen leak from the control valve of a BR22 PLUS prompted an investigation to determine root cause. The result of that investigation concluded that machining debris in the O-ring groove of the Control Valve Nut has interfered with the Oxygen seal in the valve assembly“.

Members using this equipment should download and read the bulletin, and take the actions recommended therein.

Leak Test Procedure

BR22 Plus Torch

This picture shows what a BR22 PLUS torch looks like and the location of the valve stem leak. If this is not what your torch looks like, do not continue!

BR22 Plus Torch

Outfit the BR22 PLUS torch as shown with an 18″ cutting rod inserted and the collet tightened

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.