Restricted air supply to diver
- Safety Flash
- Published on 24 July 2023
- Generated on 28 November 2026
- IMCA SF 18/23
- 3 minute read
Jump to:
During a diver recovery drill, a contracted subsea company encountered significant issues that led to the standby diver momentarily losing his main air supply.
What happened?
This restriction in the air supply resulted in the diver going on bailout and the drill being aborted. Both divers were safely recovered to the surface.
What went right?
- Both divers worked together during the recovery to amend the issues after the incident.
- When the primary air supply was restricted, Diver 1 was attentive and assisted Diver 2.
- Both divers were recovered to the surface safely.
What went wrong?
What went wrong
A review of both divers’ videos showed difficulties in recovery, primarily caused by improper umbilical management and communications.
- Human error: Diver 2 moved his umbilical restriction from the handle of Basket-2 to the handle of Basket-1, leaving just 2 m of slack between this connection and the ring on Basket-2 main wire. This led to his umbilical becoming strained between the baskets due to uneven recovery, causing a restriction in his main air supply.
- Inadequate supervision: The task plan for the drill lacked detailed and specific instructions, leaving gaps. That caused further issues when coupled with the umbilical placement, uneven recovery of the baskets, and communications issues.
- Communication breakdown: The placement of Diver 2 umbilical between the baskets was not apparent to the Diving Supervisor. The Diving Supervisor was unaware of the uncoordinated basket movement and there was inadequate communication between the divers and the diving supervisor, exacerbating the situation.
What were causes of the incident?
- Improper umbilical management: Prior to the recovery of the divers, Diver 2 moved his umbilical restriction from the handle on Basket-2 to the handle on Basket-1. Leaving Diver 2 with his umbilical connecting between Basket-1 and the ring on Basket-2 wire, causing a strain on his umbilical when Basket-1 raised before Basket-2. This led to a kink in the umbilical resulting in the loss of the main air supply to the diver.
- Communication issues: There were initial misunderstandings between the divers and the diving supervisor regarding the issues, resulting in delays in levelling the baskets to remove the strain from Diver 2’s umbilical.
- Coordination problems: When the instruction was given to recover both baskets together, LARS-2 began lifting Basket-2 while Basket-1 was not lifted. This led to Diver 2 umbilical stretching between the two baskets as Basket-2 pulled it.
Lessons learned
Our member learned the following lessons:
- Communication: Establish clear communication protocols before the operation and ensure all team members understand their roles and responsibilities. Ensuring that the crew understand their roles prevents misunderstandings and enhances overall coordination during operations.
- Supervision: Ensure adequate instructions, communications, and supervision during all operations. Particular attention should be paid during the planning, execution, and oversight of regular emergency drills.
- Umbilical Management: Proper umbilical management during all diving operations is critical. Poor umbilical management can lead to serious diver incidents and injuries.
- Continuous Improvement: Besides annual reviews, lessons learned from incident findings should be included in updates to operational procedures, manuals, and guidelines – helping to ensure that good practices are formally implemented and providing guidance to reduce potential risks in future operations.
Actions
- Ensure that lessons learnt is shared with the entire workforce and with IMCA.
- Reviewed and updated company diving procedures, training and diving manuals to include learnings outlined above.
Related Safety Flashes
-
IMCA SF 10/22
21 April 2022
-
IMCA SF 05/19
20 March 2019
-
High potential near-miss: Failure of both divers’ breathing air supply and dive stage recovery winch
IMCA SF 01/16
7 January 2016
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.