Suspected case of Legionella onboard vessel

  • Safety Flash
  • Published on 18 December 2018
  • Generated on 11 February 2026
  • IMCA SF 28/18
  • 2 minute read

Two cases of “acute pneumonia in severe form” were identified on a survey vessel with 42 persons onboard, including crew and client’s representatives.

What happened?

The client’s health team assumed it to be a case of Legionella.  The vessel went into port and both affected personnel were evacuated and sent to a medical clinic for examination. 

What were the causes?

Legionella infection is caused when bacteria gains entry into the respiratory system.  This can occur from water suspended in air in the form of a fine mist as created by showers or tap sprays.

Well maintained water tanks, pipe work, pumps and hoses, along with good water management practices can help control the legionella bacteria.  

Corrective Actions

  • Legionella and throat culture tests were arranged for all personnel onboard.
  • Swab tests were taken from the ventilation systems in the cabins of the two affected personnel.
  • Deep cleaning of all vessel cabins and washing and cleaning of all ventilation air grates (as well as pipes).
  • Appropriate cleaning chemicals were passed through the ventilation system by a specialized contractor so that air flow could assist in the disinfection process. Treatment of portable water tanks was arranged also.
  • Arranged appropriate cleaning/chlorination of cabin shower heads at quarterly intervals.

Medical test reports later confirmed that:

  • The two persons were not infected with Legionella. They were diagnosed with acute respiratory infection and appropriate medicines prescribed.
  • There were no signs of Legionella disease confirmed onboard.

Members may wish to review:

Latest Safety Flashes:

Dropped GRP cover during subsea lifting

A vessel was lifting and relocating a Pipe Line End Manifold (PLEM) GRP Top Cover when the load became detached and dropped approx. 7m.

Read more
Umbilical support frame made contact with passing vehicle on public road

Whilst travelling, a contractor transporting umbilical support frames (USFs) made contact with a passing vehicle as one of the frames dropped down.

Read more
Petrol driven equipment left stored in an emergency generator room

Stored snowblower created an unnecessary fire and explosion risk, as well as blocking access around critical equipment.

Read more
Mechanic got burns due to fire in portable generator

During refuelling, petrol (gasoline) spilled around generator and ignited.

Read more
Some positive findings and good practices

Collection of some positive findings and good practices.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.